At Rohr Eckhardt Private Limited , we specialize in the design and manufacturing of custom-built Low Voltage (LT) Panels ranging from 1000A to 6300A , engineered to meet the most demanding industrial and utility applications. With a commitment to quality and innovation, our LT Panels offer unmatched safety, flexibility, and performance under varying environmental and load conditions.
Key Features of Low Voltage Panels
✔️ Fully compartmentalized design for enhanced safety and operational clarity
✔️ Easy to install, operate, and maintain — ideal for quick commissioning
✔️ Cost-effective & space-saving architecture
✔️ High degree of safety and operational reliability
✔️ Tailored configurations to meet client-specific requirements
✔️ Aesthetic and compact design suited for modern infrastructure
✔️ Designed to comply with temperature rise limits and stringent quality standards
🔒 Safety-Focused Design
• Completely enclosed busbar chambers to prevent accidental contact • Shrouded links in feeder compartments for maximum operator protection • Dust and vermin-proof construction ensures longevity in all environments • Busbar systems built to withstand high fault levels
⚙️ Robust Applications
• Industrial complexes • Power generation & distribution setups • Commercial buildings • Utility substations • Renewable energy installations • Infrastructure projects
🛠️ Built to Last
• High ambient temperature & humidity tolerance • Rugged indoor and outdoor applications • Fixed or draw-out type up to 6300 Amps • Single or double front access options • Resistance to short circuits and thermal stress
💡 Why Choose Röhr Eckhärdt LT Panels ?
With a legacy rooted in precision and reliability, Rohr Eckhardt Private Limited delivers LT Panels that blend cutting-edge engineering with global quality benchmarks . Designed for low energy consumption and long-term performance , our panels offer you cost-efficiency without compromising on safety or functionality .
Low Voltage (LT) Panel Specifications
1000A - Click to expand ↓
Category Specification
Electrical 415V AC, 3P+N+E, 50Hz
Rated Current 1000A
Short Circuit 50kA/1sec
Busbar 2×50×10mm (Copper, tin-plated)
Main Breaker 1000A ACB (Micrologic trip)
Feeder Breakers MCCBs (250-800A)
Metering Digital energy meter, ammeter, voltmeter
Enclosure CRCA 2mm, IP42
Cooling Natural ventilation
Cable Entry Bottom/top, gland plate
Surge Protection 40kA SPD
Interlocking Mechanical
Testing IEC 61439 compliant
2000A - Click to expand ↓
Category Specification
Electrical 415V AC, 3P+N+E, 50Hz
Rated Current 2000A
Short Circuit 50kA/1sec
Busbar 2×100×10mm (Copper, tin-plated)
Main Breaker 2000A ACB (Micrologic trip)
Feeder Breakers MCCBs (250-1600A)
Metering Digital energy meter, ammeter, voltmeter
Enclosure CRCA 2mm, IP42
Cooling Natural ventilation
Cable Entry Bottom/top, gland plate
Surge Protection 40kA SPD
Interlocking Mechanical
Testing IEC 61439 compliant
4000A - Click to expand ↓
Category Specification
Electrical 415V AC, 3P+N+E, 50Hz
Rated Current 4000A
Short Circuit 65kA/1sec
Busbar 4×100×10mm (Copper, tin-plated)
Main Breaker 4000A ACB (Micrologic trip)
Feeder Breakers MCCBs (250-1600A)
Metering Digital energy meter, ammeter, voltmeter
Enclosure CRCA 2.5mm, IP42/IP55
Cooling Forced fans (optional)
Cable Entry Bottom/top, gland plate
Surge Protection 40kA SPD
Interlocking Mechanical/Electrical
Testing IEC 61439 compliant
5000A Click to expand ↓
Category Specification
Electrical 415V AC, 3P+N+E, 50Hz
Rated Current 5000A
Short Circuit 65kA/1sec
Busbar 4×125×10mm (Copper, tin-plated)
Main Breaker 5000A ACB (Micrologic trip)
Feeder Breakers MCCBs (250-1600A)
Metering Digital energy meter, ammeter, voltmeter
Enclosure CRCA 2.5mm, IP42/IP55
Cooling Forced fans (optional)
Cable Entry Bottom/top, gland plate
Surge Protection 40kA SPD
Interlocking Mechanical/Electrical
Testing IEC 61439 compliant
6000A Click to expand ↓
Category Specification
Electrical 415V AC, 3P+N+E, 50Hz
Rated Current 6000A
Short Circuit 65kA/1sec
Busbar 4×150×10mm (Copper, tin-plated)
Main Breaker 6000A ACB (Micrologic trip)
Feeder Breakers MCCBs (250-1600A)
Metering Digital energy meter, ammeter, voltmeter
Enclosure CRCA 3mm, IP55
Cooling Forced fans (mandatory)
Cable Entry Bottom/top, gland plate
Surge Protection 65kA SPD
Interlocking Electrical (auto-transfer)
Testing IEC 61439 compliant
6300A Click to expand ↓
Category Specification
Electrical 415V AC, 3P+N+E, 50Hz
Rated Current 6300A
Short Circuit 65kA/1sec
Busbar 4×150×12mm (Copper, tin-plated)
Main Breaker 6300A ACB (Micrologic trip)
Feeder Breakers MCCBs (250-1600A)
Metering Digital energy meter, ammeter, voltmeter
Enclosure CRCA 3mm, IP55
Cooling Forced fans (mandatory)
Cable Entry Bottom/top, gland plate
Surge Protection 65kA SPD
Interlocking Electrical (auto-transfer)
Testing IEC 61439 compliant
Key Differences Summary
Feature
Details
Busbar Size
2×50×10mm (1000A) → 4×150×12mm (6300A)
Cooling
Natural (≤4000A) → Forced Fans (4000A+ optional, 6000A+ mandatory)
Protection
40kA SPD (≤5000A) → 65kA SPD (≥6000A)
Mechanical → Electrical interlocking (6000A+)
Enclosure Thickness
2mm (1000A) → 3mm (6000A+)
Typical Applications
Current Rating
Applications
1000A – 2000A
Small factories, commercial complexes
4000A – 5000A
Medium industries, hospitals
6000A – 6300A
Heavy industries, power substations
1000A LT Panel (Siemens/SEIPAN)
Parameter
Specification
Additional Details
Busbar System
2×50×10mm Cu, tin-plated
Calculation: 1000A ÷ 1.2A/mm² = 833mm² → 2×50×10=1000mm² (20% margin)
Main Breaker (Siemens)
3WL1 1000A ACB with Micrologic 5.0X trip unit
Selection Criteria: 1000A continuous, 50kA Icu, 4-pole
Cable Entry
Bottom entry with 16×32mm gland plate
Option: Top entry available (specify in order)
Interlocking
Mechanical interlock between incomer & bus coupler
Siemens Part: 3TK2824-0CB4 mechanical interlock kit
Surge Protection
Siemens 5SD7 511-6 (40kA, 3P+N)
Installation: Directly mounted on busbar
CT/PT
1000/5A CT (Class 0.5 for metering, 5P10 for protection)
SEIPAN Model: SCT-1000/5
2000A LT Panel (Siemens/SEIPAN)
Parameter
Specification
Additional Details
Busbar System
2×100×10mm Cu, tin-plated
Calculation: 2000A ÷ 1.2A/mm² = 1666mm² → 2×100×10=2000mm² (20% margin)
Main Breaker (Siemens)
3WL1 2000A ACB with Micrologic 6.0X trip unit
Selection Criteria: 2000A continuous, 65kA Icu, 4-pole
Cable Entry
Dual-side entry with 20×40mm gland plate
SEIPAN Option: Customizable entry positions
Interlocking
Mechanical interlock + key exchange system
Siemens Part: 3TK2844-0CB4 with key interlock
Surge Protection
Siemens 5SD7 611-6 (40kA, 3P+N) with remote alarm contact
Coordination: Type 1+2 combined SPD
CT/PT
2000/5A CT (Class 0.2 for energy metering)
SEIPAN Model: SCT-2000/5 with DIN96mm mounting
4000A LT Panel (Siemens/SEIPAN)
Parameter
Specification
Additional Details
Busbar System
4×100×10mm Cu, tin-plated
Calculation: 4000A ÷ 1.2A/mm² = 3333mm² → 4×100×10=4000mm² (20% margin)
Main Breaker (Siemens)
3WL2 4000A ACB with Micrologic 7.0X trip unit
Selection Criteria: 4000A continuous, 100kA Icu, 4-pole with ground fault protection
Cable Entry
Top+bottom entry with 25×50mm gland plate
SEIPAN Feature: Anti-dust brush seals for IP55 compliance
Interlocking
Electrical interlock (Siemens SIRIUS 3SU1 relays)
Logic: Incomer-Coupler interlock via PLC control
Surge Protection
SEIPAN SPD-4000 (40kA, 3P+N) with thermal disconnect
Installation: Dedicated SPD compartment near incomer
Cooling System
2×120mm axial fans (Siemens 3UF7 310-0AA)
Control: Auto ON at 50°C, OFF at 40°C
5000A LT Panel (Siemens/SEIPAN)
Parameter
Specification
Additional Details
Busbar System
4×125×10mm Cu, tin-plated
Calculation: 5000A ÷ 1.2A/mm² = 4166mm² → 4×125×10=5000mm² (20% margin)
Main Breaker (Siemens)
3WL2 5000A ACB with Micrologic 7.0X trip unit
Selection Criteria: 5000A continuous, 100kA Icu, 4-pole with advanced metering
Cable Entry
Front+rear entry with cable cradle support
SEIPAN Option: Fireproof sealing compound for critical applications
Interlocking
PLC-based interlock (Siemens S7-1200) with HMI display
Function: Auto-transfer logic with priority selection
Surge Protection
Siemens 5SD7 711-6 (65kA, 3P+N) with MODBUS monitoring
Coordination: 2-stage SPD (Type 1 + Type 2)
Busbar Joints
Silver-plated bolted joints with torque markings (45Nm)
SEIPAN Standard: Infrared thermography tested during FAT
6000A LT Panel (Siemens/SEIPAN)
Parameter
Specification
Additional Details
Busbar System
4×150×10mm Cu, tin-plated
Calculation: 6000A ÷ 1.1A/mm² = 5454mm² → 4×150×10=6000mm² (10% margin)
Main Breaker (Siemens)
3WL3 6000A ACB with Micrologic 7.0X trip unit
Selection Criteria: 6000A continuous, 150kA Icu, 4-pole with arc flash detection
Cable Entry
Bottom entry with 30×60mm gland plate + cable bend radius guides
SEIPAN Feature: Integrated cable support brackets for 800mm² cables
Interlocking
Redundant PLC interlock (Siemens S7-1500) with SCADA integration
Logic: Dual-redundant interlock circuits
Surge Protection
SEIPAN SPD-6000 (80kA, 3P+N) with RS485 communication
Monitoring: Real-time SPD status via MODBUS RTU
Forced Cooling
4×150mm centrifugal fans (Siemens 3UF7 410-0AA) with dust filters
Control: VFD-driven speed control based on temperature
6300A LT Panel (Siemens/SEIPAN)
Parameter
Specification
Additional Details
Busbar System
4×150×12mm Cu, tin-plated
Calculation: 6300A ÷ 1.0A/mm² = 6300mm² → 4×150×12=7200mm² (14% margin)
Main Breaker (Siemens)
3WL3 6300A ACB with Micrologic 7.0X trip unit
Selection Criteria: 6300A continuous, 150kA Icu, 4-pole with IEC 62606 compliance
Cable Entry
Customizable entry ports with 35×70mm gland plates
SEIPAN Option: Liquid-tight cable entry systems for outdoor installations
Interlocking
SIL-3 certified interlock (Siemens Fail-Safe PLC)
Safety: Meets IEC 62061 safety requirements
Surge Protection
Siemens 5SD7 811-6 (100kA, 3P+N) with cloud connectivity
Integration: Siemens MindSphere compatible
Special Tests
Partial discharge test (<10pC) + thermographic scan during FAT
SEIPAN Protocol: Witness testing available for customer
1. Busbar Calculation Formula
Formula
Current Density
Busbar Size (mm²) = Rated Current (A) / Current Density (A/mm²)
1.2 A/mm² (≤4000A)
1.1 A/mm² (5000A–6000A)
1.0 A/mm² (6300A)
2. Breaker Selection Criteria
Criteria
Details
Continuous Current
≥ Panel Rating
Icu
≥ Short-circuit rating (50kA/65kA)
Trip Unit
Micrologic X (Siemens)
Configuration
4-pole for complete isolation
3. Cable Entry Best Practices
Practice
Specification
Minimum Bend Radius
12× Cable Diameter
Gland Plate Material
Stainless Steel (SEIPAN), Aluminum (Siemens)
Sealing
Fireproof sealing for critical areas
4. Interlocking Types
Type
Mechanical
Electrical
PLC-Based
Cost
Low
Medium
High
Flexibility
Limited
Moderate
High (programmable)
Vendor Part
Siemens 3TK28 series
Siemens 3SU1 relays
Siemens S7-1200/1500 PLC
Vendor-Specific Recommendations
Vendor
Recommendations
Siemens
Preferred for 6000A+ panels (3WL3 series with advanced protection)
Seamless integration with TIA Portal for PLC interlocks
SEIPAN
Cost-effective for ≤4000A panels
Customizable busbar layouts and cable entry options
Typical Bill of Materials (6300A Example)
Component
Siemens Model
SEIPAN Equivalent
Main ACB
3WL3 6300A
SEI-ACB6300
Surge Protector
5SD7 811-6
SPD-6300-CLOUD
CTs
5A7 1860-6AA
SCT-6300/5-HD
Cooling Fans
3UF7 410-0AA
SEI-FAN150-4P
Contact us today to configure a panel tailored to your operational needs.